98 GEMS
So O rings done, I've now got full cabin heat, but the UK weather just went tropical (for a few days, anyway), so now I need the AC... Last summer the AC worked, after I replaced the condenser and added a 2nd hand drier.
This year the AC is not playing. The compressor works, when I give 12v and and earth direct to the connector (C166P) the clutch engages, and the cabin chills as expected. In normal use though nanocom says AC grant "no", but as far as I'm aware the nanocom doesn't also tell me the AC request status - if I could find that in the nanocom menu somewhere it could help with diagnosis, and if I could force it on that would be even better. I also need to disconnect the BECM diagnostic connector as it apparently interferes with the Nanocom's interrogation of the HEVAC ECU - I haven't done that yet - but I don't know if that wd screw up the readings or not.
It crossed my mind that one of the many sensors may be feeding in rubbish data to the HEVAC ECU.
I got ambient 12.7 (fine)
aspirator 18.2 (fine)
evaporator 16.2 (ok, just replaced with a 2nd hand one off a freelander, but same Valeo part number)
heater core temp -0.20 (although it climbs once I've turned up to Hi)
Is the heater core temp way off - seems so. What range should it read in? If that were the case is that going to explain why the AC is not being requested? I recently did the o rings so cd have disturbed something on the sensor
In general any HEVAC faults I have had in the last year are clearable. I have a rare "compressor open circuit" message (but I had that last year too, when the AC was working) and the right blend motor needs fixing at some point. I have a periodic service book come up, but I think it's usually triggered by me asking the jammed blend motor to move (ie by pressing the "wrong" button to adjust the air vent flow)
Seems my first job is to get to air con grant "yes" and then I can start testing stuff... And maybe pressure test the aircon system