I have just used a vacuum coolant filler today , the top hose and bottom hoses where the only ones to collapse under vacuum, not sure if it should be more.

The vacuum held at the recommended pressure so in theory shows there isnt an air leak.

I am still desperately clinging on to the last hope of fixing my car.

Just been reading up on Heater core problems and am wondering if this could also be a possible cause of my problem, maybe its clogged or something.

Whats the best method to bypass the heater core on a Bosch?

Member
avatar
Joined:
Posts: 7823

Same as on anything else. Disconnect the two hoses that go through the bulkhead to the heater matrix and join them together with something (a couple of plumbing 90 degree bends had been used on my SE when I first got it).

Member
Joined:
Posts: 290

Was your clogged up or was someone just bypassing the leak?

Member
avatar
Joined:
Posts: 7823

O rings were shot so coolant poured out if the hoses were connected, so I just put a pair of O rings in it.