This issue has been going on for some time now, and I am at a loss as to whats going on!
Both my '99 and '02 do the same thing.
When the compressors are running, they "short cycle". By this, I mean they turn on and off in bursts of 15 seconds to a couple of minutes.
Looking at the compressor state on Nano, it shows compressor as "ON", and thermal switch as "NORMAL". It will do this from
stone cold, so not a thermal issue.....
I have several good compressors here, and they all do the same thing, so not the compressors.
The compressor relay is new, and it does cycle on and off with the compressor, so it is getting a signal to switch on and off.
If I wait a few minutes, the system will get up to pressure and the pressure switch will change state shutting off the compressor as it should.
I am looking at the EAS ECU, and I suppose the MosFet driving the relay is possibly thinking it is overcurrent and folding back the output? Looks like pin 8 from the ECU has that signal....
This is no major deal except that when the missus is doing short trips to the shops, it will eventually come up with an "Unknown Fault"
and go to extended height whilst flashing all 4 lights on the EAS switch. Probably finally runs out of air??
While I am at it, has anyone come up with an answer from Colin and his merry men about why the Nano displays an EAS fault as "Unknown"??? It can clear it fine, but not knowing why it faulted does not assist in troubleshooting!. Annoying, at best!

Member
avatar
Joined:
Posts: 7851

As long as the thermal switch stays normal, as you say, it isn't a thermal issue so the only thing left is the pressure switch. IIRC pressure switch state and compressor state are on different pages on the Nano screen, so you can't easily see if the switch changes state at the same time as the compressor kicks in. It might be worth hanging an LED across the compressor so you can easily see if they coincide. That would suggest a lack of hysteresis in the pressure switch but as you have two that are both doing the same thing, that doesn't make a lot of sense unless that is how they go with age? It should be closed at 140 psi and not open until it drops to 120 psi.

Member
Joined:
Posts: 360

I can hear the compressor when it's running, and see Nano from where I have my finger on the relay to feel it click in.
The pressure switch is not changing state according to Nano.
Relay ~randomly~ cycles the pump but pressure switch stays open until the system gets to pressure, then switch closes, and compressor is commanded off.

Member
Joined:
Posts: 634

?Try swapping relays?

Member
avatar
Joined:
Posts: 7851

So the question really isn't why does it suddenly cycle on for a short period but why does it stop in the first place if the pressure and thermal switches don't change state? My understanding is it should run until the pressure switch changes state so it stops and then only start again when the pressure has dropped. It is inhibited at certain times though which may prevent it from reaching full. Before I changed my compressor mounts so I can no longer hear it, I noticed it would sometimes run when sitting at a junction with the brakes on but stop as soon as I started moving.

Member
Joined:
Posts: 360

I have tried 3 different known to be good relays. Same result.
Will dig into it further today.
I am going to look at pin 8 on the EAS controller to see if the signal comes and goes

Member
Joined:
Posts: 360

Whilst perusing the dark side, I found this which is part of a post fron Jos G. from 2012:

"When you brake and the car is stopped, when you take your foot of the brake, the car will self level which cause the compressor to stop running. When the compressor is running and the ecu decides it want to open the solenoids, the compressor will stop to allow this and restart after the leveling procedure is complete."

This would certainly be an explanation for what I have observed. Gilbert touched upon this as well above.
I have not seen this particular behaviour described in print in RAVE or the various primers on the EAS I have seen.
Does the compressor always stop when it does a leveling adjustment?

Member
avatar
Joined:
Posts: 7851

Yes it does. That's why it will sometimes run when you have your foot on the brake pedal as that inhibits any movement, but will stop as soon as you take your foot off the brake and it levels. As long as the pressure is within the limits that it doesn't need the compressor to run to top it up, it stays off. If the pressure is low, it will restart as soon as the levelling is completed. .

Member
Joined:
Posts: 360

Ahhhh..... So that does indeed clear up the issue....It's not an issue, just another interesting "feature"
of these beasties!
Still trying to work out just why you would need to shut off the compressor before activating the valves?

Member
Joined:
Posts: 654

Bolt wrote:

Ahhhh..... So that does indeed clear up the issue....It's not an issue, just another interesting "feature"
of these beasties!
Still trying to work out just why you would need to shut off the compressor before activating the valves?

Most likely done to ensure the system can't suffer "logic race" type problems if a functional but not in absolutely perfect condition gets its inputs in the wrong order under some unspecified set of conditions.

If I recall correctly from a, thankfully exceedingly brief, encounter with pneumatic logic controls its considered best to do one thing at a time because hysteresis and operating times have inherent variability due to the system having to be able to work over a certain pressure range. An issue that can only get worse as components age.

Clive

Member
avatar
Joined:
Posts: 7851

Must have been designed by a bloke. It can only do one thing at once.....

Member
Joined:
Posts: 106

Compressor needs to stop if any of the corners are being lowered. Ait cannot enter & exit at the same time because the corner valves share a common main gallery in the valve block. If the car isn't level, it will cycle between raising some & lowering the others until targets are reached.

It's explained in the System Info Doc.

Member
Joined:
Posts: 360

Thanks for all of the information on this issue.
This will save me trying to "Troubleshoot" the system.
Hadn't come across the aforementioned document, is it part of Rave?
Happy New year!
Tom

Member
avatar
Joined:
Posts: 7851

This one enter link description here the EAS system Information document.

Member
Joined:
Posts: 360

Thanks for the link!
Good read over coffee.
Happy New year!