rangerovers.pub
The only place for a coil spring is up Zebedee's arse
Member
Joined:
Posts: 7

I have a strange issue with my P38 HVAC. The car was off the road for a couple of months due to a blown head gasket, and after the the HVAC was not blowing properly. The blend motors were replaced and calibrated, but now although the HVAC starts OK, after a while there is no air coming through the vents even though I can hear the fan running. Diagnostics do not show blend motor faults and the internal ambient and evaporator temperature sensors are new.

The system seems to work longer when cooling than heating but recently, at best, it will operate for about 60 minutes before the airflow stops - the fan still running.

I am at a loss, can anyone suggest what the problem and solution might be? Many thanks for your time, Simon

Member
avatar
Joined:
Posts: 8640

Are both fans running? If only one runs it draws air in from outside but rather than it going through the AC evaporator and heater box, the air just goes across the car and out the other side. If you poke the recirc button, it closes off the inlets so the air will then come out of the vents as it can't go anywhere else. If you take the pollen filters out, you can see the fans by looking down the hole. With the ignition in position 1, they should both start spinning.

Member
Joined:
Posts: 7

Gilbert,

Thank you very much, that sounds highly likely, I'll try the re-circ button when it happens next. I'll let you know the result.

Thank you again, very much appreciated!

Simlon

Member
Joined:
Posts: 7

Hi Gilbert, I had a couple of long drives yesterday and on both teh air stopped flowing into the car after about 50 minutes. Sadly pressing the recirc button didn't change anything - though considering what a lemon the car turned out to be it is very likely that the button doesn't work and the inlet vents didn't close. I'm going ahead with changing the fans and will update in due course. Thank you again, Simon

Member
avatar
Joined:
Posts: 8640

Make sure you an see both fans spinning by looking down the pollen filter housings first.

Member
Joined:
Posts: 7

I'll do that today - though with a query as the system works perfectly to start with, the problem only arises after some time.

Member
avatar
Joined:
Posts: 8640

The motors for the blowers are standard brush and commutator DC motors. I've had a couple where one winding or one segment of the commutator fails so they don't work if the brushes are on that segment. If you take them out and power the motor on its own, rather than running smoothly, they vibrate.

Member
avatar
Joined:
Posts: 8640

Also, check that when the airflow stops it has genuinely stopped and not that it is blowing on the screen. By default, initially the air is blown out of the dash vents and into the footwells but after a while, when the aspirator is telling it that the interior is close to the desired temperature, the distribution motor changes so the airflow comes out of the dash vents. If the distribution motor or the gears aren't properly aligned, it may be directing it all to the screen vent instead. This assumes that the blowers are still working though and the air is just going where you don't want it to go.

Member
Joined:
Posts: 7

I checked after a trip yesterday and the flow is not being directed to the screen - or anywhere else in the car, though I can feel little 'seeps' of air around joints in the dash, so teh A/C is working, just not going in the right place. Stupidly I forgot to check that the fans were both running after the trip when the problem was evident.

This still sounds a very likely explanation to me so I've ordered some replacement fans and will get them changed; I'll update when done. Thank you again for your time.

Member
Joined:
Posts: 7

Hi Gilbert, sorry this has taken so long, but I finally got the blower motors changed, and no difference unfortunately - all works fine for a while and then the air flow stops though the fans keep running. I've had it on the diagnostics a couple of times and these faults come up: 'Left Recirculation Door Motor Circuit Fault' and 'Evaporator Temperature Sensor Circuit Fault' - the latter a bit surprising as the sensor is a new genuine one installed in June, though it could be wiring, I suppose.

Do you (or anyone else!) have other suggestions about this, please? Many thanks.

Member
avatar
Joined:
Posts: 8640

It's a bit strange, if the blowers are running then the air has got to be going somewhere. Ignore the recirculate motor error, all that will do is either draw air in from outside through the pollen filter if it is open or drawing it in from the car interior if closed. Either way, it will still be blown through the AC evaporator, the heater box and out somewhere. The choices are the dash vents, the floor vents or the screen. If the trunking joints are leaking, it can leak out there (either after the blowers but before the heater box or after the heater box and before the vents) but if that was the case it would do it all the time and not after you've driven for a while.

Member
Joined:
Posts: 7

Strange indeed - thank you for your thoughts, Gilbert, it is appreciated. I've got an ex-Harwoods chap who is going to investigate over a weekend in Nov, I'll let you know what he finds (if anything). It is the 'its fine' and then 'it stops' that confuses me.