Having fixed the issues on the RT side with distribution motor, I have turned my attention to the LH side distribution flap motor.
Nano shows error as "Motor short circuit to 12 volt positive"
The motor moves the flap just fine from recirc to fresh.
I have unplugged the motor and substituted in a blend motor with a good drive. Works fine. Same error.
I found the 2 wires at the HVAC head unit plug and snipped them and attached motor directly to the plug.
Same error.
I have swapped in 2 different known good, tested working head units and same error.
What am I missing? Nothing in that circuit is shorted to positive anywhere???!